Electrical Installation Condition Report (EICR)

Electrical Installation Condition Report


This is a detailed health check of your property testing circuits and accessories to provide a detailed report.

The electrics will be checked/tested against the UK standard for the safety of electrical installations in accordance with BS7671.

If there are any dangerous or potentially dangerous conditions are found, the overall assessment of the electrical installation will be unsatisfactory. Remedial action would be required to remove any potential risk to premises/people. An estimate would then be submitted accordingly.

How often should this report be carried out?

Your electrics should be inspected and tested at regular intervals dependant on location as noted in the BS7671, Guidance note 3: Inspection and Testing (IET).

Recommendations for homeowners are once every 10 years or on buying and selling a property.

Electrical Safety Standards in the Private Rented Sector


As of 1st April 2021 it is now law to ensure that all rental properties have an Electrical Installation Condition Report(EICR) in place. For further details:

https://www.rla.org.uk/landlord
/guides/responsibilities
/electrical_inspections.shtml

If you have an EICR that has been carried out within the last 5 years, and all remedial works performed with written evidence, then you are covered, but you must ensure this is updated every 5 years (or less if Electrician has concerns), to remain compliant to the new law.

This report must be carried out by a qualified Electrician. Essential remedial works highlighted within this report must be rectified and written evidence kept as proof of work done. These remedial works must be completed within 28 days, or if deemed dangerous, as soon as practically possible.

A copy of this report should be given to your Tenant within 28 days, either by the Landlord or Agent. If requested a copy may need to be given to your local authority within 7 days. If you do not comply with these new regulations the local authority will issue an enforcement notice and possible fines.

Denis Bonnici Electricians Ltd would perform the appropriate tests to conform to the new regulations. Any essential remedial works highlighted on the report would be discussed with the Landlord/Agent and an estimate provided. Once the remedial works have been carried out we would re-issue the EICR as satisfactory and present a detailed invoice of works carried out.

PRICING: The cost of performing an EICR would depend on the number of circuits:

Up to and including 5 x circuits = £120 + Vat. Any additional circuits @£15 each + Vat.

A visual inspection of smoke alarms would also be done at the same time to ensure they are within date (if date on unit).

The Landlords and Tenant Act 1985 requires landlords of properties with short leases to keep the electrical wiring in good repair and working order.

Insurance companies may also want evidence that properties are being maintained and tested in accordance with this act.

Allow an average of 3-4 hours on site for testing

Additional Certifications


MINOR WORKS CERTIFICATE: Extension of circuits.

ELECTRICAL INSTALLATION CERTIFICATE: New installations, i.e. Consumer units and new circuits.

PART P BUILDING CONTROL CERTIFICATION: Actioned by us through ELECSA as appropriate to regulation.

PAT TESTING: Frequency as highlighted within the Code of Practice for in-service inspection and testing of electrical equipment (IET)

Domestic Installer Logo
Registered Competent Person Logo
ECA Logo
Electrical Safety Register Logo
Trustmark Logo
Institution of Diagnostic Engineers Logo
Dimplex Logo
Domestic Installer Logo
Registered Competent Person Logo
ECA Logo
Electrical Safety Register Logo
Trustmark Logo
Institution of Diagnostic Engineers Logo
Dimplex Logo